The ZMM8 series molded case circuit breakers (hereinafter referred to as “circuit breakers”) are one of the new-type circuit breakers developed by our company using mature design and manufacturing technologies. With a rated insulation voltage of 800V, they are suitable for circuits with an alternating current of 50Hz, a rated operating voltage of 690V and below (400V for ZMM1-63), and a rated operating current up to 800A, used for infrequent conversion and infrequent starting of motors. The circuit breakers have overload, short-circuit, and undervoltage protection functions, which can protect the circuits and power supply equipment from damage.The photo in the 3P MCCB ZMM8-125 MCCB

Introduction to Molded Case Circuit Breakers (MCCBs)

Molded Case Circuit Breakers (MCCBs) are core components in low-voltage power distribution systems, primarily used for overload protection, short-circuit protection, and on-off control of electrical circuits.

The rated current of Molded Case Circuit Breakers (MCCBs) typically ranges from 10A to 1600A, while some high-end industrial-grade models can extend this range up to 2500A.

Rated Operating Voltage (Uₑ) of Molded Case Circuit Breakers (MCCBs)

  • Single-phase systems: Mainly compatible with AC 230V
  • Three-phase systems: Core low-voltage power distribution class: AC 400V/415V

Tripping Modes of Molded Case Circuit Breakers (MCCBs)

  • Thermal-magnetic tripping
  • Electronic tripping
  • Residual current tripping (leakage current tripping)
  • Special tripping
  • Manual Tripping: Active Control Mode by Human Operation
  • Shunt tripping
  1. Technical data
  2. Type ZMM1-63 ZMM1-125 ZMM1-160 ZMM1-250 ZMM1-400 ZMM1-630 ZMM1-800
    Plose P 3 3,4 2,3 3,4 3 2,3,4 3,4 3,4 3,4
    Rated current In A 10, 16,20, 25,32, 40,50, 63 10, 16,20, 25,32, 40,50, 63,80, 100, 125 100,125,140,160 100, 125,140 160,180, 200225, 250 225,250,315,350,400 400,500,630 630,700,800
    Rated insulation voltage Ui V 500 800
    Rated impulsewithstand voltage Uimp V 6000 8000
    Rated operation voltage Ue V AC400 AC400/690
    Breaking capacity class L M L M L L M L M L M L M
    Limit short-circuitbreaking capacity Icu kA 230V 35 50 35 50 35 35 50 50 75 50 75 - -
    400V 25 35 25 50 35 35 50 50 65 50 65 75 75
    690V - - 8 10 8 8 10 10 20 10 20 - 30
    Working short-circuit breaking capacity Ics kA 230V 18 50 18 50 22 22 50 50 50 50 50 - -
    400V 18 22 18 25 18 18 25 35 32.5 35 42.5 50 50
    690V - - 4 5 4 4 5 5 10 5 10 - 15
    Arcing distance mm 50 100
    Operating frequency Electrical life 3000 3000 3000 3000 2000 2000 2000
    mechanical life 20000 20000 20000 20000 10000 10000 10000