Our Grow Room Temperature and Humidity Controller
It is mainly used to regulate and control the temperature and humidity inside equipment such as medium and high-voltage switchgear, terminal boxes, ring main units, and pad-mounted substations.
It effectively prevents equipment failures caused by low or high temperatures, as well as creepage and flashover accidents triggered by humidity or condensation.
Advantages
- High-precision temperature control capability
- Flexible temperature control mode switching
- On-demand start/stop, reducing energy waste
- Intelligent load adaptation, optimizing energy consumption curves
- Multiple protections to avoid abnormal risks
- Strong anti-interference ability and environmental adaptability
- High usability with a low learning threshold
- Expandable and linkage control support
-
Temperature And humidity Controller For Grow Room Technical Parameters
- WordPress Table
Power Supply Voltage (Default product power supply is AC220V, 50 - 60Hz) DC (customizable): 24V, 36V, 48V, 110V, 220V Measurement Accuracy Temperature: ±0.3°C; Temperature Resolution: 0.1°C; Humidity: ±2%RH; Humidity Resolution: 0.1% Measurement and Control Range Temperature: - 30~+100°C; Humidity: 0~100%RH Display Method Measured value and set value displayed by nixie tubes; Output status and control mode indicated by LED lights Control Mode Heating and Humidifying 1 - 1: Start when the temperature is ≤ (set value), and stop when the temperature is ≥ (set value + hysteresis). Start when the humidity ≤ (set value), and stop when the humidity ≥ (set value + hysteresis). Cooling and Dehumidifying 0 - 0: Start when the temperature is ≥ (set value) and stop when the temperature is ≤ (set value - hysteresis). Start when the humidity is ≥ (set value) and stop when the humidity is ≤ (set value - hysteresis) Heating and Dehumidifying 1 - 0: Start when the temperature is ≤ (set value), and stop when the temperature is ≥ (set value + hysteresis). Start when the humidity is ≥ (set value), and stop when the humidity is ≤ (set value - hysteresis). Cooling and Humidifying 0 - 1: Start when the temperature is ≥ (set value) and stop when the temperature is ≤ (set value - hysteresis). Start when the humidity is ≤ (set value) and stop when the humidity is ≥ (set value + hysteresis). Control Output Relay manual/automatic output: Contact capacity 250VAC 5A (resistive load) Installation Method Panel - embedded installation, base - type installation (with installation standard guide rail base) Panel - embedded installation, base - type installation (with installation standard guide rail base) Installation Dimensions 45x45mm 45x45mm Others Insulation Resistance: >100MΩ Insulation Strength: 2000VAC for 1 minute Power Consumption: <2VA Operating environment: Occasions with non - corrosive gas, where the temperature is 0 - 50°C and the relative humidity is 30 - 95% RH. -
Outline and Installation Dimensions
- WordPress Table
Outline Code 4 5 A 6 9 2 Outline Dimensions 48×48 48×96 72×72 80×80 96×96 120×120 Mounting Hole Dimensions 45×45 45×91 67×67 76×76 91×91 111×111 Description Micro - square Flat - square 72 - square 80 - square 96 - square 120 - square