3 Phase Din Rail Energy Meter DTSU2788-7P

Key features:

  1. Accurate Monitoring with Real-Time Visualizable Data
  2. Facilitating Energy Conservation and Reducing Electricity Costs
  3. Early Warning for Ensuring Electricity Safety
  4. Wide Application Adaptability and Easy Installation & Maintenance
  5. Traceable Data for Facilitating Management Decisions

Share it to:

 

Introduction:

  • Our 3 Phase Din Rail Energy Meter DTSU2788 and DSSU2788 both adopt microelectronics technology and are used to measure the active electrical energy of three-phase AC with a rated frequency of 50/60HZ.
  • They measure the electricity consumption in both forward and reverse directions equally. There are two connection methods for this series of electronic three-phase watt-hour meters: direct connection type or connection via mutual inductor type.
  • This 3 Phase Din Rail Energy Meter all the technical requirements for din-rail three-phase electric energy meters specified in the national standard GB/T17215.321-2008 《Class 1 and Class 2 Static AC Active Watt-Hour Meters》
  • Measures three – phase active electrical energy, no need for calibration during long – term operation.
  • Powered by three – phase power supply. If one wire (any one of the three wires of a three – phase three – wire electric energy meter) or two wires (any two of the four wires of a three – phase four – wire electric energy meter) is disconnected, the measurement accuracy is not affected.
  • Wide operating temperature range.
  • Has phase – failure indication function or voltage indication function
  • Display methods: counter, liquid crystal.
  • Has remote power – off function.
  • Output interface: RS485.
Technical IndexData
Rated voltage ACDTSU2788 three phase four wire 3x120/208V,3x220/380V,3x230/400V,3x240/415V
Working voltage range0.8~1.2Un
Rated current5ACT,1.5(6)A,5(60)A,10(100A,or other as required
Frequency50Hz or 60Hz
Connection modeCT type or Direct type
Displaymechanical step register or LCD
Accuracy class1
Power consumption<0.5W/5VA/each phase
Start current0.004lb
AC voltage withstand4000V/25mA for 60 seconds
Impulse voltage6kV 1.2 μs waveform
IP gradeIP20
Constant400~6400 imp/kWh
Pulse outputPassive pulse,pulse width is 80±5ms
Executive standardDIN 43880,IEC62053-21,IEC62052-11
Work temperature-30℃~70℃
Outline dimension L×M×H125x88x73mm
Operating temperature-25℃~55℃
Storage temperature-40℃~80℃
Reference temperature23℃±2℃
Relative humidity0 to 95%,non-condensing
AltitudeUp to 2500m
Warm up time10s
Mechanical EnvironmentM1
Electromagnetic EnvironmentE2
Degree of pollution2
WordPress Table

We sincerely welcome your inquiries!