Technical Functions
- Audible Alarm: Specifically for configurable local electrical measurement alarms and over – limit alarms, with a mute function (optional).
- Environmental Measurement: Temperature and humidity, specifically for independent temperature/humidity control of output relays (optional).
- Electrical Measurement: Voltage, current, frequency, active power, reactive power, apparent power, power factor, voltage – current combination, voltage – current – power combination. Other combination meters can be customized according to customer needs, with an accuracy of 0.2 class.
- Electric Energy Metering: Active and reactive energy; accuracy of 0.2 class.
- Display: Single – row LED digital display, 5 – digit/4 – digit full – screen LED digital display, 5 – digit VA monochrome LCD display, 4 – digit FSTN LCD display.
- Power Supply: AC/DC 85 – 265V, AC 220V, AC/DC 48V (customization required).
- Communication: International standard RS – 485 interface, ModBus – RTU protocol, networkable.
- Extended Functions (Optional): 2 – channel (DI) digital input, 2 – group condition – setting (DO) digital output, 3 – channel (AO) analog transmission output.
-
Technical Parameters
- WordPress Table
Product Model Specification Measurement Electric Energy Display Pulse ZM - 9AI - E(5) 96 - square Current None All - series specifications, LED nixie tube Segmented FSTN LCD ,Segmented VA LCD, Single - row LED nixie tube None ZM - 9AU - E(5) 96 - square Voltage None None ZM - 9AUI - E(5) 96 - square Voltage, Current None None ZM - 9APF - E(5) 96 - square Power Factor None None ZM - 9AP - E(5) 96 - square Active Power None None ZM - 9AME(5) 96 - square Voltage, Current, Frequency, Active Power, Reactive Power, Apparent Power, Power Factor Active energy metering Reactive energy metering 2 - channel pulse output 96 - square - Note: If the model suffix has 5, it is 5 – digit full – screen LED digital display/segmented VA LCD display; if there is no 5, it is 4 – digit full – screen LED digital display/segmented FSTN LCD display.
- The table only lists the 96 – type single – phase current/voltage/multi – function. Other specifications are all included. For specific models, please refer to the “Model Naming Meaning”. All kinds of combination meters can be customized according to user requirements.
- Peripheral Functions
-
Peripheral Functions
- supsystic-tables id=40
-
Outline and Installation Dimensions
- supsystic-tables id=41
-
Single – phase Combination Function Optional Configuration Table
WordPress TableIdentifier U I F P Q S PF EP EQ Function Voltage Current Frequency Active Power Reactive Power Apparent Power Power Factor Active Energy Reactive Energy
-
-
Ordering Instructions
- Order Example
- When signing the contract, please specify in detail the product model, input signal, wiring method and other information. If there are no special requirements from the customer, the instrument will be configured according to the factory default.
- Model: ZM – 9AU – E (96 – type single – phase digital voltmeter)
- Input: 380V
- Communication Interface: RS – 485 interface, ModBus – RTU protocol